NHBC Standards 2006

8.2 Wall and ceiling finishes

MATERIAL STANDARDS

8.2 - M1Material standards
8.2 - M2Plastering
8.2 - M3Plasterboard and dry lining
8.2 - M4Ceramic wall tiling

8.2 - M1
All materials shall:
(a) meet the Technical Requirements
(b) take account of the design
 

Materials that comply with the design and the guidance below will be acceptable for wall and ceiling finishes.

Materials for wall and ceiling finishes should comply with all relevant standards, including those listed below. Where no standard exists, Technical Requirement R3 applies (see Chapter 1.1 'Introduction to the Standards and Technical Requirements').

References to British Standards and Codes of Practice include those made under the Construction Products Directive (89/106/EEC) and, in particular, appropriate European Technical Specifications approved by a European Committee for Standardisation (CEN).

PLASTERING

8.2 - M2
Materials for plastering shall be adequate for the location and intended use
 

Items to be taken into account include:

(a) plasters

Relevant standards include:

BS 1191Specification for gypsum building plasters
BS 5270Part 1 Specification for polyvinyl acetate (PVAC) emulsion bonding agents for indoor use with gypsum building plasters.

(b) materials for render

Relevant standards include:

BS EN 197Specification for Portland cements
BS 1199
and 1200
Specifications for building sands from natural sources.

(c) metal laths and beads

Relevant standards include:

BS 405Specification for uncoated expanded metal carbon steel sheets for general purposes
BS 1369Steel lathing for internal plastering and external rendering.

(d) plastic compound finishes

Plastic compound finishes containing asbestos should not be used.

PLASTERBOARD AND DRY LINING

8.2 - M3
Materials for plasterboard and dry lining shall be adequate for the location and intended use
 

Relevant standards include:

BS 1230Gypsum plasterboard

Recommendations regarding materials for use in dry lining work are included in:

BS 8212Code of Practice for dry lining and partitioning using gypsum plasterboard.

CERAMIC WALL TILING

8.2 - M4
Materials for ceramic tiling shall be adequate for the location and intended use
 

Relevant standards include:

BS EN 98Ceramic floor and wall tiles.