8.2 Wall and ceiling finishes
Appendix 8.2-A | |
Dry lining to receive ceramic wall tiling |
Appendix 8.2-A
Dry lining to receive ceramic wall tiling
Dry lining to receive ceramic wall tiling | ||||||
Description | Board thickness mm | Support centres mm | Additional support | Max. height mm | Comments | |
Timber frame | 12.5, 15 | 400 to 450 600 | No Timber noggings 600 mm centres vertically | 3600 3600 | ||
Timber battens | 12.5, 15 | 400 | Battens at head, base and intermediate positions not exceeding 1200 mm centres | 3600 | ||
Direct bond | 9.5 | 450 dabs of adhesive in rows | Horizontal dabs at mid-storey height | 3600 | Complete at least 10 days before tiling | |
Direct bond (Thermal laminates) | 12.5, 15 | 600 dabs of adhesive in rows | Horizontal dabs at mid-storey height | 3600 | Complete at least 10 days before tiling | |
Metal furring | 12.5, 15 | 400 metal furring sections | Metal furring stops at head, base and intermediate positions not exceeding 1200 mm centres | 3600 | Complete at least 10 days before tiling | |
Resin base adhesive (Thermal laminates) | All | Blob of sealant | 9 nailable plugs per board | |||
Independent steel stud lining 48 mm 60 mm | 2 x 12.5 2 x 12.5 | 400 | Mid-point support Mid-point support | 3000 3600 | ||
48 mm metal stud partitions 70 mm metal stud partitions 146 mm metal stud partitions | 15 2 x 12.5 each side 2 x 15 each side 15 2 x 12.5 each side 2 x 15 each side 2 x 15 each side | 400 400 400 400 600 | Additional stud at 300 mm up to tile height | 2700 3600 3600 3600 3600 3600 3600 | ||
Prefabricated gypsum wallboard panel partition | 57 63 | Normal specification | 2700 | |||
Laminated partition | 50 65 | Normal specification | 2600 2800 | Complete at least 10 days before tiling |